Sheet
A-101
Title
Capabilities
Scale
NTS
Issued
2026-08-22

Every way in ends at the same set.

Start from an address, from a brief, or from geometry you already own. The intake changes what you supply. It does not change what arrives.

01 / 00 31 00Three ways in

Start where you already are.

01

An address

Give the engine a parcel and a program. It resolves the zoning envelope, solves the massing against it, and returns a feasibility answer with the drawings attached — early enough to still change the pro forma.

OUT · Envelope, massing, SD set
02

A brief

Unit mix, storeys, target area, structure type. The engine designs the building: core placement, circulation, the structural grid, and the egress that has to work before any of it is worth drawing.

OUT · Generated building, any phase
03

Your own footprint

You already have the plan and you want the other eighty sheets. Bring the geometry; the engine enriches it into a coordinated, cited, consultant-complete set drawn against your design.

OUT · Full CD set from your plan

The intake changes what you supply. It does not change what arrives: the same title blocks, the same citations, the same ledger.

02 / 00 31 00What each phase carries

SD, DD, CD — issued, not previewed.

Each phase is a real issue with a real revision table. You take the SD set to the owner, the DD set to the consultants, and the CD set to the reviewer who has to seal it.

PhaseWhat is resolved
SDMassing against the parcel, the zoning envelope, unit mix, core placement, the structural grid and the egress diagram.
DDAssemblies get real: wall types with ratings and R‑values, sections cut through actual construction, and the consultant disciplines drawn against the same model.
CDSchedules, keynotes, details and the coordinated discipline sheets. Cross references resolve across the set.
03 / 00 31 00The disciplines

Eight disciplines, one model.

The consultant sheets are not imported PDFs sitting next to the architectural set. They are drawn from the same graph, which is what makes a duct and a joist disagree on screen instead of on site.

89 · Sheets in the reference CD set

Counts below are from a CD-phase render of an L-shaped multifamily infill. Set size varies with the building.

SeriesDisciplineSheets
GGeneral — cover, code data, life safety, index14
AArchitectural — plans, elevations, sections, wall types, schedules, details61
SStructural — foundation, framing, schedules
MMechanical
EElectrical — power, lighting
PPlumbing
FPFire protection — sprinkler plans, all levels
LLandscape
S · M · E · P · FP · L combined11
04 / 00 31 00Details and hand-off
ItemWhat ships
Details67 templates — 35 exterior, 20 interior, 12 DD wall sections. Each one is data: dimensions live in the spec, geometry is drawn from primitives.
Sheet sizeARCH‑D (24×36) or ARCH‑E (30×42).
FormatsPDF and DXF. DWG on request. IFC for the model.
LedgerEvery determination the set rests on, with citation, inputs and confidence.
QA reportWhat the verification pass re-derived, and what it wants a person to confirm.
TurnaroundA full CD render completes in 20 seconds. Review is the long pole, and it should be.

A detail is a promise to a framer.

Adding a detail is a new file, not an engine change — so the library grows without anyone touching the code that renders your set.

67Detail templates
43Sheet renderers

What it will not do is part of the specification.

Preliminary — for review by the design professional of record.
Not for construction or permit submission until reviewed and sealed.
  • It does not seal. No licence number, no signature, no stamp graphic — not as a placeholder, not in a demo.
  • It does not submit. A set goes to a jurisdiction when a licensed professional decides it is ready.
  • It does not replace a survey or a geotechnical report. Where the set depends on site data it does not have, it says so on the sheet.
  • It does not decide what the code leaves to an official’s discretion. Those go to the reviewer flagged, not resolved.
Architect’s seal Unsealed